Description
The quantitative information provided by the pH value expresses the degree of the activity of an acid or base in terms of hydrogen ion activity. The pH value of a substance is directly related to the ratio of the hydrogen ion [H+] and the hydroxyl ion [OH-] concentrations. The H+ concentration is greater than OH-, the material is acidic; i.e., the pH value is less than 7. If the OH- concentration is greater than H+, the material is basic, with a pH value greater than 7. If equal amounts of H+ and OH- ions are present, the material is neutral, with a pH of 7. Acids and bases have free hydrogen and hydroxyl ions, respectively. Lutron pH Meter Price in Bangladesh
Features Lutron pH Meter Price in Bangladesh
Build in temperature sensor for auto temperature compensation (ATC).
pH 4, pH 7 standard solution are standard accessories.
Easy to change the pH electrode.
Temperature measurement, C, F.
IP67, water proof and protection.
Auto calibration for pH 4, pH 7 or pH 10 or other value.
High input impedance.
LCD with two displays and bar graph indicator.
Data hold function for freezing the desired value.
Auto power off. Lutron pH Meter Price in Bangladesh
Records max. and min. value with recall.
100 point data logger with recall.
Microcomputer circuit, intelligent function, high accuracy.
Compact size, light weight.
Power supply by DC 1.5 V battery ( UM4/AAA ) x 4 PCs
Available for wide applications, such as aquarium, beverage, fish hatcheries, food processing, photography, laboratory, quality control, school & colleges, swimming pools, water conditions.
Learn more about pH meters
pH Measurement
These indicators have limitations on their accuracy, and can be difficult to interpret correctly in colored or murky samples.
A pH measurement system consists of three parts: a pH measuring electrode, a reference electrode, and a high input impedance meter. The pH electrode can be thought of as a battery, with a voltage that varies with the pH of the measured solution. The pH measuring electrode is a hydrogen ion sensitive glass bulb, with a millivolt output that varies with the changes in the relative hydrogen ion concentration inside and outside of the bulb. The reference electrode output does not vary with the activity of the hydrogen ion.
The pH electrode has very high internal resistance, making the voltage change with pH difficult to measure. The input impedance of the pH meter and leakage resistances are therefore important factors. The pH meter is basically a high impedance amplifier that accurately measures the minute electrode voltages and displays the results directly in pH units on either an analog or digital display. pH Electrodes Lutron pH Meter Price in Bangladesh
pH electrode technology has not changed much in the past 50 to 60 years. With all the technological advancements of the last 30 to 40 years, pH electrode manufacturing remains an art. Not a terribly advanced nor “high tech” process but a very critical and important step in the electrode manufacturing. In fact, the thickness of the glass determines its resistance and affects its output.
Temperature Compensation
Temperature compensation is contained within the instrument, because pH electrodes and measurements are temperature sensitive. The temperature compensation may be either manual or automatic. With manual compensation, a separate temperature measurement is required, and the pH meter manual compensation control can be set with the approximate temperature value. With automatic temperature compensation (ATC), the signal from a separate temperature probe is fed into the pH meter, so that it can accurately determine pH value of the sample at that temperature. So
Buffer Solutions Lutron pH Meter Price in Bangladesh
Buffers are solutions that have constant pH values and the ability to resist changes in that pH level. They are used to calibrate the pH measurement system (electrode and meter). There can be small differences between the output of one electrode and another, as well as changes in the output of electrodes over time. Buffers are available with a wide range of pH values, and they come in both premixed liquid form or as convenient dry powder capsules. So
Most pH meters require calibration at several specific pH values. One calibration is usually performed near the isopotential point (the signal produced by an electrode at pH 7 is 0 mV at 25°C), And a second is typically performed at either pH 4 or pH 10, It is best to select a buffer as close as possible to the actual pH value of the sample to be measured. So
Best Quality & No Compromise So so so so so so so so so so
We are always providing the best quality Scientific Laboratory Equipment. We always try to supply our clients with the original Brand & Quality tested products with service; Scientific Laboratory equipment in Bangladesh online store – www.jadubazar.com So so so so so so so so so so
Our Facebook Page Click Here So so so so so so so so so so